SolarEdge 300 Watt Power Optimizer
	IN: Helios H4
	OUT: MC4
	Manufacturer Part Number: OP300-MV-AH4SM-2NA
SolarEdge power optimizers offer a superior approach to maximizing the throughput of photovoltaic systems using module embedded electronics. With superior efficiency (99.5%) even in mismatched and unshaded conditions and a flexible system design for maximum space utilization, these optimizers can offer a 25% increase in power output over a traditional central inverter.
Features
	- Module level MPPT - optimizes each module independently
 
	- Dynamically tracks the global maximum operating point for both modules and PV inverter
 
	- Module-level monitoring for automatic module and string level fault detection allowing easy maintenance 
 
	- Electric arc detection - reduces fire hazards
 
	- Unprecedented installer and firefighter safety mode - safe module voltage when inverter is disconnected or off
 
	- Connection of one or more modules to each power optimizer
 
	- Lower installation costs with faster design, less wiring, DC disconnects and fuses
 
	- Easy and flexible installation – use the same installation methods as exist today
 
	- Allows parallel uneven length strings and multi-faceted installations
 
	- Allows connection of different module types simplifying  inventory considerations 
 
	- Immediate installation feedback for quick commissioning
 
Specifications
| 
Input | 
OP250-LV  | 
OP300-MV/OP400-MV | 
| 
Rated Input DC power  | 
 
250   | 
 
300 / 400 W | 
| 
Absolute Maximum Input Voltage (Voc)   | 
 
55 Vdc  | 
 
75 Vdc | 
| 
MPPT Operating Range  | 
 
5 - 55 Vdc   | 
 
5 - 75 Vdc | 
| 
Maximum Input Current   | 
 
10 Adc | 
 
10 Adc | 
| 
Reverse-Polarity Protection  | 
Yes | 
| 
Maximum Efficiency   | 
 
99.5 % | 
| 
European Weighted Efficiency   | 
98.8 % | 
| 
CEC Weighted Efficiency   | 
98.7 % | 
| 
Inductive Lightning Protection  | 
1 m / ft | 
| 
Overvoltage Category   | 
II | 
| 
Output During Operation (Power Optimizer connected to operating inverter) | 
| 
Maximum Output Current  | 
15 Adc | 
| 
Operating Output Voltage   | 
5 - 60 Vdc | 
| 
Total Maximum String Voltage (Controlled by Inverter) - US and EU 1-ph | 
500 Vdc | 
| 
Total Maximum String Voltage (Controlled by Inverter) - EU 3-ph | 
950 Vdc | 
| 
Output During Standby (Power Optimizer Disconnected from Inverter or Inverter off) | 
| 
Safety Output Voltage per Power Optimizer | 
 
1 Vdc
 | 
| 
PV System Design | 
| 
Minimum Number of Power Optimizers per String (1 or More Modules per power optimizer) | 
8 (1-ph system) / 16 (3-ph system) | 
| 
Maximum Number of Power Optimizers per String (1 or More Modules per power optimizer) | 
Module power dependent; typically 20 - 25 (1-ph system)  / 45 - 50 (3-ph system) | 
| 
Parallel Strings of Different Lengths or Orientations | 
Yes |