Schneider Electric C12 - 12 Amp 12 Volt PWM Charge Controller

Manufacturer Part Number: RNWC12

The Schneider Electric RNWC12 charge, lighting, or load controller is uniquely sophisticated. As a charge controller, it features three-stage charging, user definable voltage parameters, and automatic equalization. Standard in the C12's load control circuitry are field adjustable low voltage disconnect and reconnect points, along with a five minute low battery disconnect warning. The Xantrex C12 also functions as a lighting controller. Lighting run time is adjustable from 2 to 8 hours or can be set from dusk to dawn operation. It is used worldwide in a variety of applications, including remote village lighting systems and automatic outdoor lighting in Africa, Latin America, and Asia. An optional battery temperature sensor ensures precise battery charging regardless of battery temperature fluctuations.

Features

The C12's field configurability and feature packed design makes it the only small PV controller you need!

  • Ensures your batteries are always charged
  • Silent, pulse width modulated microprocessor control (maximizing battery life)
  • Field adjustable voltage and battery set points
  • Electronic protection against short-circuit, overload, over temperature and reverse polarity conditions.

Applications

  • Village Power
  • Cabin/Vacation Homes
  • Outdoor Area Lighting
  • Sign Lighting
  • Bus Shelters
  • Telecommunication

Specifications

Charge Controller RNWC12
PV Amps (Max.) 12 A at 12 VDC only
DC Load (Max.) 12 A with auto reset
Operating Voltage (Min.) 6 V
Voltage Drop - PV to Battery (Max.) 0.3 V
Voltage Drop - Battery to DC Load (Max.) 0.15 V
Regulation Setting 13 to 15 VDC
Equalize Setting Bulk plus 1 V for two hours
Consumption while charging (typical) 0.007 A
Consumption at night (typical) 0.003 A
Consumption with load disconnected (typical) 0.003 A
Stranded wire size (Max.) #10 AWG stranded (5.4 mm2)
Allowed Temperature Range 32° F to 104° F (0° C to 40° C)
Enclosure Type Powder coated steel with strain relief for wiring and knockouts for up to three 1/2" conduits
Unit Weight 2 lb (0.9 kg)
Shipping Weight 2.5 lb (1.13 kg)
Dimensions (H x W x D) 6.25" x 4.3" x 1.5" (16.5 x 11 x 4 cm)
Shipping Dimensions (H x W X D) 8" x 4.6" x 1.6" (20.3 x 11.7 x 4 cm)
Mounting Vertical wall mount - indoor
Warranty Two years

Detailed Description

Photovoltaic Charge Controller

  • Silent, solid state, series pulse width modulated (PWM) charge control with 3-stage (bulk, absorb, & float).
  • Field adjustable set points with removable knobs to reduce tampering (bulk range: 13.0 to 17.0 VDC).
  • Electronic short circuit, overload, over temperature and reverse polarity protection improves reliability.
  • Automatic reset of overload protection system--eliminates problems of tripped breakers and blown fuses.
  • High efficiency, "No diode" design without electronics in the negative conductors (as per NEC code).
  • Optional plug-in/replaceable temperature compensation sensor, ideal for sealed batteries.
  • Continuous rating of 12 amps at 113F /45C and 8 amps t 150F/65C for severe environments.
  • Designed for 15 amps of short-circuit PV array current (typically about four 50 watt modules).
  • Two stage lightning and surge suppression through both active and passive protection components.
  • Equalize mode (t bulk+1DC for 2 hours) with automatic activation every 30 days or if LVD is reached (defeatable).

DC Load Controller

  • Automatic low voltage disconnect (LVD) with adjustable set point (LVD range 10.5 to 12.5 VDC).
  • Automatic low voltage reconnect (LVR) with adjustable set point (LVR range 12.0 to 14.0 VDC)
  • Selectable automatic or manuals reconnection of loads after low voltage disconnect occurs.
  • Electronic short-circuit, overload, over temperature and reverse polarity protection improves reliability.
  • Continuous rating of 12 amps at 113F /45C and 8 amps at 150F/65C for severe environments.
  • Low voltage disconnect warning system blinks loads on-off-on when the battery voltage is below the low voltage disconnect setting after a two minute delay. Loads are then disconnected after a 5 minute additional time delay unless loads have been reduced and voltage has risen above the low voltage disconnect set point.
  • Manual reset switch on bottom of enclosure allows one-time 10 minute grace period for operation of DC loads after reset has occurred. Additional pushes have no effect until voltage reaches the low voltage reconnect setting.

Automatic Lighting Controller

  • Automatic control of lighting systems with nighttime detection by using the PV array as a photocell.
  • Adjustable run duration from 2 to 8 hours or "dusk to dawn" all night operation of lights, unless LVD is reached.
  • Electronic short-circuit, overload, over temperature and reverse polarity protection improves reliability.
  • Continuous rating of 12 amps @ 113F /45C and 8 amps @ 150F/65C for severe environments.
  • Manual reset switch on bottom of enclosure allows testing of lights during daytime or after LVD has occured.