The 10.0kw & 12.0kw isolated inverters have all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real-time power tracking and energy harvesting, as well as regular high performance efficiencies of up to 97.3%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. The high frequency isolated topology allows this unit to be lightweight and compact in size to help with transportation and installation. The unit is free of electrolytic capacitors, leading to a longer product lifetime. This rugged outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions.
Features
‘Electrolyte-free’ power converter to further increase the life expectancy and long term reliability
True 3-phase bridge topology for DC/AC output converter
Night Wake up button to access energy harvesting data and error log
Dual input sections with independent MPP tracking, allow optimal energy harvesting from two subarrays
oriented in different directions
High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting
Flat efficiency curves ensure high effi ciency at all output levels insuring consistent and stable performance
across the entire input voltage and output power range
Anti-Islanding Protection
Watertight NEMA 4X enclosure
Integrated disconnect in compliance with NA Standards (-S and -S2 Versions)
RS-485 communication interface (for connection to laptop or datalogger)
Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP
Specifications
MODEL
PVI-10.0-I-OUTD-US-208
PVI-10.0-I-OUTD-US-480
INPUT
Start-up Input Voltage (Vdcstart)
adj. 120...350 V
Operating Input Range (Vdcmin...Vdcmax)
0.7 x Vdcstart...520 V
MPP Input range (Vmppmax,f-Vmppmin,f) at full power
220...470 V
220...470 V
Absolute Maximum Input Voltage Vmax,abs
520 V
520 V
Number of Independent MPPT
2
2
Maximum Input Current (Idcmax)
24.0 A
24.0 A
Number of DC Inputs Pairs
2 (3 on -S2 version) for each MPPT
INPUT PROTECTION
Reverse Polarity protection
Yes
Input Short Circuit Current
29.0 A
Input Side Varistors
4 (2 for each MPPT)
Photovoltaic Array Isolation Control
GFDI
DC Switch
600 V / 32 A
OUTPUT
AC Grid Connection (Vacmin...Vacmax)
Three Phases
Rated Power (Pac,r)
10,000 W
10,000 W
Power at 45°C/113°F
9,600 W
10,000 W
Power at 60°C/140°F
7,250 W
8,960 W
Rated Grid Voltage (Vac,r)
208 Vac
480 Vac
AC Voltage Range
183...228 V
422...528 V
Maximum Output Current (Iac,max)
30.0 A
14.0 A
Rated Frequency (fr)
60 Hz
60 Hz
Nominal Power Factor
> 0.99
Total Harmonic Distortion
< 2%
OUTPUT PROTECTION
Anti-islanding protection
According to UL 1741
Maximum AC Overcurrent Protection
35.0 A
20.0 A
AC Side Varistors
3 plus gas arrester
Night Time Disconnect
Yes
Detailed Description
Designed for commercial usage, this three-phase inverter is unique in its ability to
control the performance of the PV panels, especially during periods of variable weather
conditions. This device has two independent MPPTs and efficiency ratings of up to 97.3%.
The HF isolation allows positive or negative ground confi guration. Versions are available
with fully-integrated DC and AC disconnect options. The unit is free of electrolytic capacitors,
leading to a longer product lifetime.
This isolated inverter is optimized for use in any application that requires PV array grounding, such as some thin-film models. This inverter has also been designed to serve all countries and regions with specific field-configurable set-ups available for all major country grid codes and display languages.