Enphase IQ 8 > 245 Watt MC4 Micro Inverter - IQ System
The IQ8 micro inverters from Enphase are designed to handle 235 to 350 watt solar panels. The IQ8 is compatible with 60-cell solar panels.
240 Split Phase ONLY
IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions.
|
Model
|
IQ8-60-2-US
|
|
Series
|
IQ8
|
|
Manufacturer
|
Enphase Energy
|
|
NOTE: To ensure the best installation experience, Enphase is requiring that installers complete IQ8 training and certification online
to enable IQ8 system commissioning in the field. For Enphase PV-certified installers, IQ8 training is an add-on qualification course and
for those who are non-certified installers you can access the training by completing an online assessment through
Enphase University.
We recommend having 100% of your installers take this certification course if you do Enphase installations.
|
Mechanical
|
Type
|
Grid Tie - Micro Inverter
|
|
Ambient Temperature Range
|
-40°C to +65°C
|
|
Approved for wet locations
|
Yes
|
|
Enclosure
|
Class II double-insulated, corrosion resistant polymeric enclosure
|
|
Environmental category / UV exposure rating
|
NEMA Type 6 / outdoor
|
|
Cooling
|
Natural Convection - No fans
|
|
Connectors
|
MC4
|
|
Dimensions (W x H x D)
|
8.3" x 6.9" x 1.2"
|
|
Weight
|
2.38 lbs
|
|
Shipping Method
|
Ground
|
Input (DC)
Commonly used module pairings:
Recommended PV Power (STC)
|
235 W - 350 W
|
|
Module compatibility
|
60-cell/120 half-cell
|
|
MPPT voltage range
|
27 – 37 V
|
|
Operating range
|
25 - 48 V
|
|
Min/max start voltage
|
30 V / 48 V
|
|
Max input DC voltage
|
50 V
|
|
Max DC short circuit current (module Isc)
|
15 A
|
|
Overvoltage class DC port
|
II
|
|
DC port backfeed under single fault
|
0 A
|
|
PV array configuration
|
1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit
|
Output (AC)
|
Peak Output Power
|
245 VA
|
|
Maximum continuous output power
|
240 VA
|
|
Nominal (L-L) voltage/range²
|
240 V / 211-264 V
|
|
Maximum continuous output current
|
1 A @ 240 V
|
|
Nominal frequency
|
60 Hz
|
|
Extended frequency range
|
47 - 68 Hz
|
|
AC short circuit fault current over 3 cycles
|
5.8 Arms
|
|
Power factor at rated power
|
1.0
|
|
Maximum units per 20 A branch circuit
|
16 (240 VAC)
|
|
Overvoltage class AC port
|
III
|
|
AC port backfeed current
|
30 mA
|
|
Power factor setting
|
1.0
|
|
Power factor (adjustable)
|
0.85 leading ... 0.85 lagging
|
Features
Easy to Install
- Lightweight and compact with plug-n-play connectors
- Power Line Communication (PLC) between components
- Faster installation with simple two-wire cabling
High productivity and reliability
- Produce power even when the grid is down
- More than one million cumulative hours of testing
- Class II double-insulated enclosure
- Optimized for the latest high-powered PV modules
Grid-forming
- Complies with the latest advanced grid support
- Remote automatic updates for the latest grid requirements
- Configurable to support a wide range of grid profiles
- Meets CA Rule 21 (UL 1741-SA) requirements
Detailed Desription
Enphase's newest IQ8 Microinverters are the industry’s first grid-forming microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is a proprietary application-specific integrated circuit (ASIC) that enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems.
Also known as:
IQ 8
IQ8-60-2-US
IQ8 60
IQ Eight